Can two flat rooflights be fitted side by side?
Yes, and it is a common arrangement — but the interesting part is not the two units, it is the strip of roof between them. That strip has to carry structure, drain properly and be detailed as carefully as the outer edges, and where a pair of flat rooflights goes wrong it goes wrong in the middle. The alternative is one larger unit, which removes the strip and introduces different problems instead.
Three ways to do it, and they are not variations of one another
People arrive at this having pictured two rooflights next to each other and assumed that is one decision. It is three, and they behave differently on the roof, in the room and on the price.
| Arrangement | What is between them | Where it suits | The risk it carries |
|---|---|---|---|
| Two separate units, roof strip between | Finished roof covering, over structure, with its own fall | Where joists dictate the bays, or where the budget prefers two small lifts to one large one | A narrow gutter-like zone that ponds and collects debris if the fall is not designed |
| Two units on a shared kerb | A single common upstand with a dividing rail | Where the two are meant to read as one opening from inside | The dividing detail becomes the weather line, and not every system has a good one |
| One larger unit | Nothing | Where the structure allows the span and access allows the lift | Trimming, weight, craneage, and a single point of failure in the glass |
The strip is a gutter whether you designed it as one or not
Put two kerbs a short distance apart and you have created a channel. Water from both units runs into it, water from any higher roof runs into it, and wind blows debris in but cannot blow it out. If the roof’s fall runs across the strip rather than along it, the channel has no outlet and holds water permanently.
So decide before anything is built which way that strip drains and where that water goes — a fall along the strip to an outlet, or a strip wide enough to fall across. What it never means is leaving it to chance because both kerbs are individually correct.
How narrow can the gap be?
The rule, and what sets it
The rule: the gap between two kerbs must be wide enough to build and maintain, not merely wide enough to look right on a drawing. Someone has to dress the covering up both faces, weld or bond the corners, and later get a hand in to clear it.
What sets the minimum: the covering. Welded single ply needs room to work along both upstands; torch-on felt needs room to use a flame safely beside two timber kerbs; a liquid or GRP system is the most forgiving of a narrow gap and the least forgiving of a wet week. Our guide to single ply, felt and GRP has the detail.
The trap: a gap wide enough to build but too narrow to drain. That is the worst of both, and it is where we find standing water and soft decking on roofs only a few years old.
What a pair looks like from inside
Two rooflights over one room do not read as one big one cut in half. The ceiling gets two shafts with a band of plasterboard between them, and that band is wider than people picture — it holds the kerb faces, the insulation and the reveal build-up on both sides, not just the gap between the panes.
Whether that looks deliberate or accidental comes down to symmetry and the reveal: a splay on the inner faces narrows the band, a square reveal emphasises it. Our reveal design page covers what each shaft shape does to the light, and it is worth settling before the ceiling is set out.
Matching two units that should look identical
Treat the two as one purchase. Order both skylights together, from the same supplier and the same production run, with identical glass and the same coating on the same face. Panes from different batches can differ subtly in tint, and a coating that varies between two units is invisible on a data sheet and perfectly visible in a ceiling. The same goes for frame finish, and there is no fixing that afterwards short of replacing one of them.
Setting the pair out
- Let the joist bays propose the spacing. A pair in adjacent bays with the strip over a joist is the cheapest version of this job — no trimming, and the structure under the strip is already there.
- Centre the pair, not each unit. The eye reads the group, and two shafts symmetrical about the room’s centre line look deliberate even if neither is centred on anything.
- Decide the strip’s drainage before the kerbs are built, including whether an additional outlet is needed.
- Check the fall runs the same way under both, so one unit is not sitting in the other’s run-off.
- Set both kerbs from one datum, then check diagonals on each and alignment between them — two kerbs individually square can still be out of parallel.
Exposure makes the strip harder, not just wetter
Two kerbs side by side channel wind as well as water. Air accelerating between and over the raised units produces local suction along the strip and at the four inner corners — already the worst place on a flat roof for uplift. Out towards the harbour mouth, where wind arrives off open water with no fetch break, that is a real item in the fixing schedule rather than a theoretical one; our wind uplift guide sets out how it is answered. Inland at Broadstone the same pair is unremarkable, and the strip’s problem is drainage and pine debris.
Two units or one — how we would decide it
If the structure allows a single opening without heavy trimming and the unit can get onto the roof, one is usually simpler: fewer metres of upstand, fewer corners, no strip to drain. If the joists say otherwise, or the lift is awkward, or the room wants two pools of light, a pair is not a compromise — it just has to be designed as a pair from the start.
We price both and say which we would do and why, as a fixed written price after survey with the strip’s drainage written in rather than assumed. Our installation carries a ten-year workmanship guarantee — a workmanship guarantee, and not insurance backed. Ring 01202 923272 with the room dimensions and the joist direction.
Related reading
Broadstone and Creekmoor roofs where standard specification is right
Standard specification is the right answer here, and we will say so Most of this site argues that a flat…
Can a flat rooflight be fitted from inside?
Effectively no — not the part that keeps water out. A flat roof rooflight is weathered by dressing the roof…
Can a flat rooflight be fitted to a shed or outbuilding roof?
Yes, and it is usually the simplest work we do Yes. A flat rooflight goes into a garage, workshop, garden…
Can a flat rooflight be retro-fitted to an existing flat roof?
Yes — retro-fitting into an existing flat roof is the majority of this work, not the exception. What decides whether…
Can I fit a flat rooflight to a felt roof?
Yes, and felt is one of the more forgiving coverings to detail Yes. A flat rooflight can be fitted to…
Do flat roof rooflights leak?
A properly detailed one does not No. A flat roof rooflight that has been detailed properly does not leak, and…