Can a VELUX be fitted to a flat roof?

The short answer

Not as it comes. A standard pitched-roof unit needs a slope of roughly fifteen degrees or more to shed water properly, and a flat roof does not have one. There are three ways round that, and two of them are usually better than the one people ask for.

A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

The question turns up constantly across Poole, because the housing stock is full of flat-roofed rear extensions, garage conversions and 1960s and 1970s additions. Hamworthy, Creekmoor, Canford Heath and the post-war estates around them have thousands of them, and the room underneath is almost always the darkest in the house.

The three routes, compared

Route What it is Best for Watch out for
Pitched unit on a kerb A timber or proprietary upstand built to give the unit the pitch it needs Matching an existing roof window elsewhere on the house, or where you want an opening sash you can lean through It stands proud and looks like what it is; the kerb detail and its insulation do more work than the window
A purpose-made flat roof unit A unit designed for low and zero pitch, with its own kerb and cover A clean answer where you want the manufacturer’s own solution and an opening option Sizes and options are a different range from the pitched one; do not assume a code carries across
A flat glass rooflight A different product entirely, laid on a kerb with a slight fall Most flat roof extensions, most of the time, particularly where the look matters It is a different service and a different specification conversation, covered in its own part of this site

Why the minimum pitch exists

A pitched-roof window is a drained assembly, not a sealed one. It expects water arriving on the glass to run off, and any water that gets past the outer seal to run down and out through the drainage path at the sill. Lay that assembly nearly level and neither of those things happens reliably. Water sits on the glass, debris sits with it, and the drainage path has nothing pulling water through it.

That is why the fifteen degree figure is not a suggestion from a cautious manufacturer. It is the angle below which the design stops doing what it was drawn to do.

What a kerb actually has to achieve

  1. Raise the unit to at least its minimum pitch, measured in the direction water will run.
  2. Carry the covering up its face, whether that is felt, single ply or glass-reinforced polyester, and turn it over the top in a detail that will not peel.
  3. Continue the roof insulation up and around it, so the kerb is not a cold collar around the opening.
  4. Carry the vapour control layer without breaching it, which is the part that gets skipped and the part that causes interstitial condensation.
  5. Resist wind uplift, which on the exposed flat roofs at the harbour mouth is a bigger number than most people expect.

Wind is the local constraint, not rain

A raised unit on a flat roof is a sail. On the sand spit at Sandbanks and Studland, and on the open frontage at Mudeford and Portland, wind arrives with nothing to break it, and a kerb-mounted window presents a vertical face to it. The fixing schedule and the covering termination matter more there than the glazing specification does. Inland at Broadstone or Verwood the same detail is far less demanding, and we will not charge you for exposure you do not have.

What about the room underneath?

An opening sash on a flat roof gives you ventilation from the highest point in the room, which is where warm stale air collects, and that is a genuine advantage over a wall window. What it does not give you is a view, because you cannot see out of something above your head at a shallow angle.

If the point of the exercise is daylight in a dark kitchen or a converted garage, a fixed flat glass rooflight will usually deliver more of it for less money and less protrusion. If the point is ventilation, or a rooflight you can put your head out of to clean, the kerb-mounted window earns its place.

Retro-fitting to an existing flat roof

The deck decides this, not the window

Before any of the three routes is available, the existing deck has to be sound enough to build a kerb on and to fix into. On 1960s and 1970s extensions across the Poole estates the honest finding is often that the deck and covering are near the end of their life anyway.

When that is the case, the sensible order is to re-cover the roof and install the skylight as part of the same operation. Cutting a new opening into a covering with two years left in it means doing the perimeter detail twice.

Getting it specified properly

We survey the deck, the covering type and the fall before recommending any of the three routes, because the answer genuinely changes with all three. You get a fixed written price afterwards, and our own workmanship carries a ten-year guarantee, given directly by us and not insurance backed.

We install VELUX units alongside other manufacturers’ products and hold no accreditation, approved status or partnership with any of them. On a flat roof that independence matters, because the right answer is often not the brand the question started with. Call 01202 923272 and tell us what the roof is covered in.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272