Why is my VELUX letting in water at the bottom?

The short answer

In most cases it is not a leak. Water at the bottom of a roof window is usually condensation running off the glass, or a blocked drainage channel in the sash, and those two account for the majority of what gets reported to us as a leaking skylight.

A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

That matters because the remedies point in opposite directions. Condensation is cured by ventilation and heat; a blocked drain is cured with a soft brush; a genuine leak means the junction with the roof has to be opened up. Guessing between them wastes money in every direction.

Work out which one you have

When the water appears What it looks like Most likely cause First move
Cold mornings, no rain A line of droplets on the glass, running to the bottom bar Condensation Ventilation and heating pattern, not the roof
Heavy or prolonged rain only Water collecting along the bottom of the sash, then overflowing inward Blocked drainage channel Clear the channel with a soft brush
Driving rain from one direction Damp at the head or the top corners as well as the sill Flashing or underfelt collar detail Needs looking at from outside
Any rain, worsening over months Staining on the reveal below the sill, timber discolouring Apron flashing or the tile course below it Survey, before the timber suffers
Only when it has been windy Sudden wetting rather than a gradual build Ventilation flap open, or a gasket no longer compressing Check the flap latches and the handle pulls down square

The drainage channel, and why it blocks here

There is a drainage path built into the bottom of the sash and frame, designed to collect anything that gets past the outer seal and return it outside. It is small, it is invisible from the room, and it fills.

What fills it depends on where you are. Under the pine canopy in Canford Cliffs and Branksome Park it is needles and resin, arriving all year rather than for six weeks in autumn, knitting into a mat that water cannot pass. Out on the spit at Sandbanks and around Mudeford it is salt crystal and wind-blown sand. Inland at Broadstone or Wimborne it is ordinary dust and moss, and it takes considerably longer.

Why condensation gets mistaken for a leak

Two tests that separate them in a morning

Is the glass itself wet, or only the frame? Condensation wets the whole inner pane and runs down it. A leak wets the frame, the reveal or a corner while the glass stays dry.

Does it happen without rain? Water on a cold, dry morning is not coming from the sky. A roof window is the coldest surface in a warm room, so it is the first place moisture in the air will condense, and a loft bedroom or a bathroom generates plenty of it.

The leaks that are real

When it is genuinely ingress, the cause is nearly always the junction rather than the window. The apron at the sill may have been laid over the wrong tile course. The underfelt collar that returns water to the underlay may never have been fitted at all, which is the classic signature of a unit installed by a general builder rather than a roofer. A tile below the window may have slipped. A gasket may have taken a set and stopped sealing.

None of those is cured with sealant, and sealant is what most of them have already had. Mastic round the outside of a rooflight traps water where it can do more damage and buys a season at most.

What you can safely do yourself

  1. Rotate the sash to the cleaning position and secure it before touching anything.
  2. Look along the bottom of the sash and frame for the drainage channel, and clear it with a soft brush. Nothing sharp, and nothing sprayed.
  3. Check the ventilation flap latches properly and that its filter is not blocked solid.
  4. Dry everything, then watch what happens over the next fortnight and note the weather when water returns.
  5. Photograph where the water appears. A photograph of a wet corner tells us more than a description of one.

When to stop investigating and call

Timber that has gone soft changes the timescale. A damp patch is an inconvenience; a rafter end or a sill that gives under a fingernail is rot, and it does not improve on its own. If the staining has spread beyond the reveal onto the ceiling, or the timber has darkened rather than simply marked, it has been going on longer than the symptom suggests and it wants looking at now rather than in spring.

What a visit involves

We diagnose from outside as well as inside, because half of these causes are invisible from the room. Where the junction has to be opened up we say so before starting, and the price is fixed in writing after the survey rather than discovered afterwards. Our own workmanship carries a ten-year guarantee, given directly by us and not insurance backed.

Call 01202 923272 and tell us when the water appears rather than where you think it comes from. That single piece of information sorts most of these into the right column before anyone gets on a ladder.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272