The short answer

Because nothing is holding it. A centre-pivot sash stays where you put it through friction in the pivot hinge, not through a catch or a stay, and that friction has been reduced by wear, by contamination, or by somebody lubricating it.

A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

The last of those is the most common and the most fixable, which is the good news. The bad news is that the instinctive response to a stiff roof window is to reach for a can of spray lubricant, and that is precisely the thing that converts a stiff window into one that will not stay open at all.

Why lubricant makes it worse

The friction surface in the hinge is doing a job. It is not a bearing and it is not meant to be slippery; it is meant to grip enough to hold the weight of a glazed sash at any angle. Spray oil into it and you remove the grip on purpose. The window feels marvellous for a fortnight and then starts creeping shut on its own.

If that is what happened on your window, say so when you book. The remedy is the same but the cleaning is more involved, because the lubricant has to come out of the mechanism before friction can be restored.

What to check before calling anyone

  1. Look at the hinge track along the side of the sash with the window in its cleaning position. Grit, dust and, near the water, white salt crystal all show up clearly.
  2. Clean it with a dry cloth or a soft brush. Do not add anything.
  3. Try the window again. On a fair proportion of units, particularly in the wooded belt where pine debris gets everywhere, that is the whole fault.
  4. Check whether the sash is heavier than it was. A pane replaced with a laminated or triple-glazed unit weighs more than the original and the hinge was set for the original.
  5. Check the other window in the same room if there is one. Two units of the same age behaving differently points at the hinge; both behaving the same points at age.

When cleaning does not fix it

Most generations of roof window provide an adjustment at the hinge that restores friction, set against the actual weight of your sash. Once that adjustment has reached its limit, the friction components themselves are a spare part rather than a reason for a new skylight.

Neither of those is a job we would encourage a householder to do. It is carried out on an open sash, at height, with the window in a position where a slip means a heavy glazed panel swinging. The full mechanism and the service routine around it are set out in the servicing guide in this hub.

When it is not the hinge at all

What you have What holds it open What failure looks like
Centre-pivot, manual Friction in the pivot hinge Creeps shut slowly from any angle
Top-hung, manual A stay or spring mechanism at the sides Drops suddenly rather than creeping, or will not hold at the wide setting
Electric or solar The chain actuator holds position under power Closes on its own, or will not hold; usually a control, power or rain sensor issue rather than a mechanical one

A powered unit that closes by itself in light drizzle is not faulty. It is a rain sensor doing exactly what it was fitted to do, and on the harbour side of Poole a sea mist will trigger one just as readily as rain will.

Why it matters more than an irritation

Two reasons to deal with it

Safety. A large glazed sash swinging shut while someone is leaning through the opening is a genuine hazard, particularly on the taller sizes. Where children use the room, a restrictor fitted at the same visit is worth considering.

Ventilation. A window that will not stay open stops being used, and a rooflight that is never opened stops contributing to the ventilation of the room. Condensation problems in loft rooms very often start as a hinge problem that nobody thought was urgent.

Getting it sorted

Call 01202 923272 and describe how it behaves: creeping or dropping, from any angle or only when wide open, and whether anything has been sprayed into it. That description is usually enough for us to tell you whether it is a clean, an adjustment or a part.

Repairs carry our own ten-year workmanship guarantee, given directly by us and not insurance backed, with the price fixed in writing after we have seen it.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset