GGL, GGU, GPL and GPU: the difference the middle letter makes
The middle letter of a VELUX type code says how the window opens and the last letter says what it is made of, and on the Poole coast the last letter is the one that decides how long it lasts.
Two letters do almost all the work in a VELUX type code. The middle one says how the window opens; the last one says what it is made of, and near salt water that is the letter that decides its service life.
Ask three people in a Poole loft what is above their heads and you will get three answers: a roof window, a rooflight, a skylight. All three are describing the same aperture. The type code is the only one of the four that tells you something a photograph cannot, because it describes behaviour rather than appearance. A GGL and a GPU of the same size look broadly similar from the pavement and behave completely differently once you are living under them.
How the code is built
| Position | What it says | Common values |
|---|---|---|
| First letter | The product family | G for a roof window |
| Middle letter | How the sash moves | G centre-pivot, P top-hung with a pivot function, D balcony, I fixed element |
| Last letter | Frame and sash material | L lacquered pine, U white polyurethane over a timber core |
Put together, GGL is a centre-pivot window in lacquered pine, GGU is the same opening action in white polyurethane, GPL is top-hung in pine and GPU is top-hung in polyurethane. Four products, two decisions.
Centre-pivot: what the G in the middle gives you
A centre-pivot sash rotates about a hinge roughly halfway up the frame. Push the top, the bottom swings out, the top swings in. It is the cheapest action to make, the most common by a long way, and it has two practical consequences that matter more than the price.
The first is that it can be rotated fully for cleaning, so the outer face of the glass can be washed from inside the room. On a two-storey Poole semi that is the difference between a ladder and a cloth. The second is less welcome: when the window is open, part of the sash is inside the room, at roughly head height if the window is set low. Under a sloping ceiling in a converted loft, that is a real object in real space, and it is why a centre-pivot is a poor choice directly over a desk, a bed head or the top of a staircase.
Top-hung: what the P in the middle gives you
A top-hung sash hinges at the head and swings outward and upward, so the whole opening leaf clears the room. You can stand at the window and lean into the opening, which is why top-hung units are the right answer where the window is low enough to look out of properly, or where furniture sits underneath.
The trade-off is cleaning access and pitch. Top-hung units retain a pivot function so the glass can still be turned for cleaning, but the operation is a two-stage one rather than a flick. They also sit in a narrower band of roof pitches than centre-pivot units, which rules them out at the steep end. On the steeply pitched Victorian roofs around Lower Parkstone and Westbourne that limit is worth checking before anyone gets attached to the idea.
The rule, and its exception
The rule: choose the action by where the window sits in the room. High in the slope, out of reach, used mainly for light and background ventilation, choose centre-pivot. Low in the slope, used for a view and fresh air, with anything underneath it, choose top-hung.
The exception: escape provision. Where a roof window is being counted as an emergency escape opening from a loft room, the clear opening it produces is a regulated dimension and the opening action is part of how that clear opening is achieved. That requirement outranks preference, and it is settled with building control rather than in a showroom.
The last letter is the durability decision
This is the part of the code that matters most across our service area, and it is the part most often left to whatever the supplier has in stock.
An L unit is pine with a clear lacquer. It is warm to look at, it takes a stain or a paint, and it wants maintenance: a light sand and a recoat every few years, more often where sun and salt are working on it. A U unit has the same timber core wrapped in a white polyurethane skin with no visible joints. It needs washing and nothing else, and the surface does not open up at the corners the way a lacquered finish eventually does.
| Exposure zone | Towns in it | What we specify and why |
|---|---|---|
| Sand spit | Sandbanks, Studland, Mudeford | Polyurethane, without hesitation. Salt-laden wind arrives with no land to break it, and a lacquered timber face here is a maintenance commitment most owners do not keep up |
| Coastal and harbour | Hamworthy, Southbourne, Christchurch, Lower Parkstone | Polyurethane for bathrooms and any elevation facing the water; lacquered pine is defensible on a sheltered rear slope if the owner wants the timber look |
| Cliff and wooded | Canford Cliffs, Branksome Park | Either finish performs. The canopy strips most of the salt, and the real enemy here is organic debris in the drainage channel rather than the frame surface |
| Inland | Broadstone, Creekmoor, Canford Heath, Wimborne | Lacquered pine is entirely adequate and costs less. Specifying a marine answer here is an overcharge and we will say so |

Humidity indoors beats salt outdoors
There is one situation where the polyurethane answer is correct regardless of which zone the house sits in, and that is a bathroom, a shower room or a utility. The moisture load on the inside face of a roof window in a family bathroom is relentless, and it attacks a lacquered timber sash from the room side where nobody looks until the finish lifts.
This catches people out in the inland towns, where the exterior exposure argument does not apply and the interior one does. A Broadstone bungalow with a shower room in the roof wants a U unit for reasons that have nothing to do with the sea.
Two ways the same window gets wet
From outside: salt, ultraviolet and wind-driven rain work on the lacquer at the sash corners and the bottom rail. The failure shows as a grey, opened grain that will not take a wipe clean, and the cure is stripping and recoating before it goes further.
From inside: warm moist air condenses on the coldest strip of the frame, which is the bottom rail, and sits there. The failure shows as blackening under the lacquer where no amount of surface cleaning reaches it. Extract ventilation fixes the cause; a polyurethane sash removes the consequence.
Mixing types on one roof
There is no rule against putting a top-hung unit in one bay and a centre-pivot in the next, and on a long loft room it is often the sensible answer: the top-hung one where you stand and look out, the centre-pivot one further up the slope where you only want light. From outside, the two read as a matched pair, because the visible frame profile is the same family.
What does need to be consistent is the finish and the flashing family. A pine unit next to a white one looks like an accident even when it was a decision, and two different flashing families in one row complicates the detail between them.
What changes when you go electric or solar
The same type letters carry through to the powered versions, with additional characters identifying the operation. The important practical point is that an electric or solar-powered unit is a different window, not an accessory bolted to a manual one, and the decision has to be made before the order rather than after the plaster is on. There is a separate question about converting an existing manual window, which is covered in its own answer page because the honest reply is longer than a sentence.

Choosing without the code in front of you
- Decide the action first, from the room: is anything under the window, and can you reach it comfortably?
- Decide the finish second, from the exposure zone and the room use, not from the price list.
- Check pitch against the action you chose, because pitch can veto a top-hung unit outright.
- Check escape requirements if the room below is a habitable loft room.
- Only then look at size, which is a separate code and a separate guide.
We hold no VELUX accreditation and make no claim to one. VELUX is a manufacturer’s trade mark and the type codes above are theirs, not ours. We are an independent installer, which means the advice on this page is not steered by a supply arrangement. If a different make suits your roof better, we will tell you that instead.
Getting it settled on site
All four of these letters can be argued about in the abstract. On a roof they usually settle themselves within ten minutes: the pitch rules something out, the room rules something in, and the zone decides the finish. What we put in writing afterwards is a full reference, a fixed price and a ten-year guarantee on our own workmanship, stated plainly as not insurance backed. Call 01202 923272 or send a photograph of the existing plate on WhatsApp and we will start from what is actually there.
Related reading
Can a VELUX be converted from manual to electric?
Usually yes, if the unit is from roughly the last twenty years. A retro-fit kit replaces the top control bar…
Can a VELUX be fitted to a flat roof?
Not as it comes. A standard pitched-roof unit needs a slope of roughly fifteen degrees or more to shed water…
Can a VELUX be fitted to a roof with solar panels?
Yes, but it stops being a roofing question and becomes a clearance and sequencing one. A flashing needs a clear…
Can a VELUX be replaced with the same size unit?
Usually yes. The standard size grid has been stable for decades, so a like-for-like frame is normally available, but “same…
Can a VELUX window be repaired?
Yes, more often than not. Glass, gaskets, filters, handles, friction components and flashings are all replaceable on their own. The…
Can I fit a blind to an old VELUX window?
Usually yes, provided you can read the size and type codes off the data plate. Manufacturer blinds are made to…