Reading a VELUX size code: what CK04 and MK08 actually mean
A VELUX size code is two measurements written as four characters: the letter gives the width, the digits give the height, and everything else about the window sits elsewhere on the plate.
A VELUX size code is not a model number. It is two measurements written as four characters, and once you can read it the rest of an order stops being guesswork.
People arrive at this code from one of two directions. Either they are replacing a unit that is already on the roof and want the new one to drop into the same hole, or they are pricing a first installation and a supplier has asked what size they want. The two questions look the same and they are not. VELUX is one manufacturer among several making what the trade calls a rooflight and most homeowners call a skylight, and its size code belongs to the manufacturer, not to the category. A code will get you a window. Only a measured opening will get you the right one.
The letter is the width, the digits are the height
Read CK04 as C-K-04. The first letter sets the width in centimetres. The second letter identifies the size series, and on the current UK range it is K so consistently that most people read the four characters as one word. The two digits set the height, again in centimetres.
So CK04 is 55 cm wide by 98 cm high, and MK08 is 78 cm wide by 140 cm high. That is the whole system. It is unusually honest for a product code, because nothing in it is marketing.
| Width letter | Frame width |
|---|---|
| C | 55 cm |
| F | 66 cm |
| M | 78 cm |
| P | 94 cm |
| S | 114 cm |
| U | 134 cm |
The height digits run in the same plain way: 01 is 70 cm, 02 is 78 cm, 04 is 98 cm, 06 is 118 cm, 08 is 140 cm and 10 is 160 cm. Not every letter pairs with every number. The very tall heights are not offered in the narrowest widths, because a window 55 cm wide and 160 cm high would be a letterbox rather than a window.
The sizes you actually meet on a Dorset roof
Out of that grid, a handful of codes account for most of what is already fitted across Poole and the surrounding towns. Knowing which ones are common is useful, because a common size is a size that will still be made in ten years.
| Code | Width | Height | Where it usually turns up |
|---|---|---|---|
| CK02 | 55 cm | 78 cm | Small bathrooms, box rooms, over a stair half-landing |
| CK04 | 55 cm | 98 cm | The default narrow unit where rafter centres are tight |
| FK06 | 66 cm | 118 cm | Loft conversions in interwar semis, in pairs |
| MK04 | 78 cm | 98 cm | Bedrooms where head height under the purlin is limited |
| MK06 | 78 cm | 118 cm | The most-fitted size in the range, by a distance |
| MK08 | 78 cm | 140 cm | Main bedrooms, anywhere a view is the point |
| PK08 | 94 cm | 140 cm | Wide openings, usually where a rafter has been trimmed |
| SK06 | 114 cm | 118 cm | Large rooms, almost always structurally trimmed |
| UK04 | 134 cm | 98 cm | Wide and shallow, under a low purlin |
The code describes the frame, not the hole
This is where most self-ordered windows go wrong. The measurements in the code are the outer frame. The structural opening in the roof has to be a little larger than that, by something in the order of 40 to 45 mm in each direction, and the exact figure is published per size. A frame lifted from an old unit and offered up to a new opening will not tell you this, because the old opening was cut for the old frame and the old frame is no longer in it.
If you are pricing a new installation and you have a rafter spacing rather than an opening, the sum runs the other way: take the clear gap between rafters, subtract nothing for optimism, and see which width letter fits. On roofs at 600 mm centres a 55 cm C width is genuinely marginal once the rafter thickness is taken off. On the 400 and 450 mm centres common in trussed post-war roofs, nothing fits without trimming.
Older units and the codes that came before
Measure it, do not infer it
Not every VELUX on a roof in Poole carries a four-character code in the current format. Units fitted in the 1980s and 1990s may show a three-character code, and a small number of legacy sizes were expressed as three digits with no letter at all. Those older designations do not always map cleanly onto anything in the current range.
The rule we work to is simple. If the code is current, use it and confirm it with a tape. If the code is old, unreadable, painted over or missing, the code is now irrelevant and the opening gets measured properly. A guessed size on an order form becomes a return, a delay and an open roof.

What the size code deliberately leaves out
The size is only one of four things a full VELUX reference carries, and the other three matter as much. A supplier quoting on a size alone is quoting on a quarter of the specification.
| Part of the reference | What it settles | Why it matters here |
|---|---|---|
| Type code, before the size | How the window opens and what the frame is made of | Decides whether you get lacquered pine or a white polyurethane finish, which is the main durability question near the water |
| Size code | Frame width and height in centimetres | Decides whether the roof has to be structurally opened up or not |
| Pane code, after the size | The glazing specification and factory-fitted options | Decides solar gain, acoustic performance and safety glass, and cannot be changed later without a new sash |
| Flashing code, ordered separately | How the unit meets the tile, slate or stone around it | A correct window with the wrong flashing leaks, and the flashing is not in the box |
We cover the type letters and the flashing families in their own guides, because both carry enough consequence to deserve the space. The short version: the size gets the window through the hole, and the other three decide whether it performs.
Reading the plate without taking the window apart
The data plate is a small metal or printed label on the frame, and on a centre-pivot unit the usual way to see it is to swing the sash to its cleaning position and look along the top of the sash or the head of the frame. On some units it sits behind the ventilation flap. It is worth a photograph rather than a note, because the pane code beside the size is easy to transcribe wrongly and impossible to check later from memory.
If the plate has been painted over during a redecoration, a careful clean with a soft cloth and a little white spirit usually brings the print back. If it has not, nothing is lost that a tape measure cannot recover.
Poole housing stock and the sizes it tends to allow
The service area does not have one roof type, and the size that suits a house depends more on its decade than on its postcode. Interwar and Victorian roofs around Parkstone and Westbourne were cut on site, with rafters at generous and often irregular centres, purlins running through and enough spare structure to trim an opening without drama. Those roofs take the M and P widths comfortably.
Post-war estate housing across Canford Heath, Creekmoor and Broadstone is a different proposition. Trussed rafters at close centres carry load as a designed system, and cutting one is a structural alteration rather than a carpentry job. On those roofs the honest starting point is often a narrower unit that fits between trusses, or a pair of narrow units rather than one wide one.
Two narrow windows are not half a wide one. A pair of CK04 units in adjacent rafter bays gives a very different quality of light from a single PK08 of similar total glass area. The pair throws two separate pools of light with a shadow between them; the single unit washes one wall. Which you want depends on the room, and it is a decision worth making on site rather than on a spreadsheet.

Where the code helps and where it stops helping
A size code is at its most useful in three situations: matching a replacement sash to an existing frame, checking that a quote is for the window you discussed, and working out whether a blind or an accessory will fit. It is at its least useful when someone is trying to skip a survey with it.
We have no manufacturer status with VELUX and we do not claim any. We are an independent installer who fits their units alongside other makes, which means we have no reason to steer a roof towards one brand when another suits it better. What we will do is read the plate on your roof, measure the opening it sits in, and tell you plainly whether the size you have been quoted is the size the roof will take.
What happens at survey
- The existing plate is photographed if there is one, and the code recorded in full including the pane digits.
- The structural opening is measured internally, rafter face to rafter face and head to sill, rather than being taken from the frame.
- Rafter or truss centres and member depths are recorded, because these decide whether a wider size is available at all.
- The roof covering is identified by type and profile depth, which sets the flashing family before any window is ordered.
- Pitch is measured, since the standard pitched-roof units have a minimum below which they should not be fitted.
- You get the full reference in writing, with a fixed price, before anything is bought.
That last point is the one that matters commercially. The quote is fixed after the survey, and our own workmanship carries a ten-year guarantee, given directly by us and not insurance backed. If you would rather talk it through before booking anything, call 01202 923272 and describe what is on the roof now.
Related reading
Can a VELUX be converted from manual to electric?
Usually yes, if the unit is from roughly the last twenty years. A retro-fit kit replaces the top control bar…
Can a VELUX be fitted to a flat roof?
Not as it comes. A standard pitched-roof unit needs a slope of roughly fifteen degrees or more to shed water…
Can a VELUX be fitted to a roof with solar panels?
Yes, but it stops being a roofing question and becomes a clearance and sequencing one. A flashing needs a clear…
Can a VELUX be replaced with the same size unit?
Usually yes. The standard size grid has been stable for decades, so a like-for-like frame is normally available, but “same…
Can a VELUX window be repaired?
Yes, more often than not. Glass, gaskets, filters, handles, friction components and flashings are all replaceable on their own. The…
Can I fit a blind to an old VELUX window?
Usually yes, provided you can read the size and type codes off the data plate. Manufacturer blinds are made to…